GEWU DOCUMENTATION
GW-GC-D Intelligent Steel Cable-driven Double Hinged Gate
Professional integrated gate for complex canal control and multi-sensor automation. Learn the product capabilities, first-use steps and support options.
What should I know about GW-GC-D Intelligent Steel Cable-driven Double Hinged Gate?
Professional integrated gate for complex canal control and multi-sensor automation. Learn the product capabilities, first-use steps and support options.
1. Product Overview
This integrated measurement‑control gate is specially designed for modern smart water conservancy and smart agriculture. It applies to paddy fields, terraced fields, irrigation channels and other scenarios to realize precise water control, intelligent regulation and remote management. By integrating IoT technology, solar power‑supply system and multi‑mode control functions, it effectively addresses pain points of traditional gates including high manual‑maintenance costs and severe water‑resource waste. It supports water‑saving, efficiency improvement and digital transformation for water conservancy and agriculture.
Product Features:
- Low construction cost
- All‑metal structure
- Intelligent anti‑jamming
- Intelligent safety protection
- 4G nationwide cellular network
Application Scenarios:
- High‑standard farmland construction
- Channel irrigation control, etc.
2. Core Functions
Multi‑mode Intelligent Control
- Remote Control: Supports WeChat Mini Program, API and PC‑based platform for real‑time monitoring and operation. Gate opening degree and open/close status can be remotely adjusted for unattended management.
- Local Electric / Manual Control: Equipped with emergency hand‑crank, screen control panel, operation buttons and BLE low‑power Bluetooth control. Manual adjustment is available upon power failure or network anomaly to guarantee continuous irrigation.
- Automatic Regulation Mode: Supports upstream‑water‑level or downstream‑water‑level linkage control (automatic adjustment according to preset water‑level values) to satisfy diversified requirements.
High‑efficiency & Energy‑saving Design
- Solar Power Supply: Combination of high‑power photovoltaic panel and large‑capacity gel battery. No external power source required; stable operation is guaranteed during successive rainy days.
- Low‑power Motor: Driven by high‑performance DC motor; gate opening‑closing speed>4 mm/s, balancing efficiency and energy consumption.
Durability & Reliability
- Upgraded Material: Gate body and gate leaf adopt high‑strength aluminum‑alloy frame with stainless‑steel wire ropes. Excellent corrosion resistance enables operation under harsh environments such as severe cold and saline‑alkali conditions.
- Sealing & Protection: Elastic silicone sealing structure combined with multi‑layer protection design for water‑leakage prevention and anti‑jamming performance, ensuring long‑term stable operation.
Precise Monitoring & Data Management
- Optional Expansion: Integrate water‑level sensors, flow meters and other devices for real‑time collection of flow and water‑level data. Linkage with smart water‑service platform is supported to provide reference for irrigation decision‑making.
- Data Management: Supports historical‑data query and push of exception alarms (e.g. low battery, equipment fault) to improve management efficiency.
3. Technical Specifications
Basic Parameters
| Item | Parameter |
|---|---|
| Product Model | GW‑GC‑D |
| Supply Voltage | Configurable according to gate dimension and requirements |
| Solar Module | Configurable according to gate dimension and requirements |
| Operating Current | 0.02 A |
| Ingress Protection | IP65 |
| Operating Temperature | ‑40~70 ℃ (excluding display screen) |
| Display | 7‑inch IPS capacitive touch screen, optional |
| Material | Aluminum‑alloy gate body & leaf Stainless‑steel wire ropes Silicone waterproof sealing strip Spray‑painted galvanized sheet‑metal enclosure |
Communication Parameters
| Item | Parameter | Remarks |
|---|---|---|
| Cellular Network | 4G nationwide cellular network | |
| Near‑field Communication | Low‑power Bluetooth | |
| Physical Interface | RS485 | Baud rate: 9600 8N1 |
| Communication Protocol | MODBUS | Custom non‑standard protocols available |
Button Definition
| Button | Function |
|---|---|
| Power | Power‑on / Power‑off / Emergency Stop |
| UP | Open gate |
| STOP | Halt gate movement |
| DOWN | Close gate |
4. Dimension Drawings
Gate leaf: 1300*900 mm, Maximum opening height: 1300 mm

For quotation, please provide parameters below:
| No. | Parameter | Example | Remarks |
|---|---|---|---|
| 1 | Gate Leaf Dimension | 600*600 mm | |
| 2 | Maximum Opening Height | 200 mm | |
| 3 | Touch‑screen | Required | Optional |
| 4 | Sensor | Electronic water‑level gauge | Optional |
5. Installation Procedures
Pre‑installation Preparation
Technical Disclosure
- Familiarize yourself with design drawings, installation specifications and gate technical parameters. Confirm installation position, orientation and elevation.
- Verify gate dimension (e.g. 600×600 mm) and embedded‑part specifications against drawings.
Tools & Materials
- Tools: Electric welder, spirit level, lifting equipment (chain block, crane etc.), spanners, screwdrivers, multimeter, etc.
- Materials: Sealant, bolts, gaskets, waterproof cables, grounding wire, etc.
Foundation Inspection
- Check position, verticality and levelness of foundation or embedded parts (anchor bolts, guide rails) to meet requirements.
- Remove rust and debris from foundation or embedded‑part surfaces to ensure flat mounting surfaces.
Gate‑body Installation
Lifting & Positioning
Lift the gate steadily to installation position by lifting equipment. Keep uniform clearance (normally 2‑3 mm) between gate leaf and guide rails. Calibrate verticality with spirit level; allowable deviation ≤2 mm/m.
Fastening & Connection
- Fasten gate onto embedded anchor bolts with symmetric tightening to avoid uneven stress.
- Connect gate and guide rails via welding or bolting (per design requirements), ensure gate opens/closes without jamming.
- For concrete troughs, secondary pouring is acceptable; extra fixing hardware is not required.
Sealing Inspection
Apply sealant to contact surfaces between gate leaf and gate frame. Inspect rubber water‑stop strip for intactness and no damage.
Measurement‑Control System Installation
Electrical Wiring
Connect power cables and control signal cables (RS485 etc.) per wiring diagram. Implement cable waterproof treatment (waterproof connectors, sealed conduits).
Lightning Protection & Grounding
The metal frame of gate shall be reliably grounded; grounding resistance ≤4 Ω.
Commissioning & Testing
Manual Commissioning
Switch to manual mode. Operate hand‑crank to test smooth gate movement; check for abnormal noise or jamming.
Electric Commissioning
Power on the unit. Operate full‑open / full‑close via control‑panel buttons. Calibrate zero‑point and full‑range of opening‑displacement sensor. Test remote open‑stop‑close operations via WeChat Mini‑Program or cloud platform. Test overload‑protection function (simulate rotor stall and verify automatic power‑off of motor).
Automatic Joint Commissioning
Connect to cloud platform. Test response speed and accuracy of linkage between water‑level / flow signals and gate actuation.
Acceptance & Hand‑over
Functional Acceptance
- Verify gate tightness (no water leakage upon full closure), opening‑closing speed and control accuracy.
- Validate normal performance of remote control and fault‑alarm functions (power‑off, overload etc.).
Document Hand‑over
Submit installation records, commissioning reports, equipment user manual and warranty documents.
Operation‑maintenance Training
Train operators on routine maintenance (lubrication, dirt removal) and fault‑handling procedures.
⚠️ Precautions
- Avoid bumping against gate coating and sealing components during installation.
- Take rain‑proof measures during rainy‑season construction to prevent moisture ingress into electric components.
- Keep personnel away from moving gate parts during commissioning to avoid mechanical injury.
Note: The above steps serve only as reference. Installation shall be adjusted flexibly according to actual site conditions.
6. Operation Guide
6.1 Remote Control
Mini‑Program Remote Operation
Supports plot‑mode and list‑mode selection
- Plot‑mode allows editing based on actual field plots for intuitive browsing; list‑mode supports quick search.

- Real‑time monitoring of equipment status, battery voltage, gate state, upstream‑ and downstream‑water‑level.

- Under manual‑control mode: tap Open / Stop / Close to operate the gate.

- Historical‑data query: gate‑status statistics, equipment operation logs, etc.

Automatic‑mode Setup Upstream‑ / downstream‑water‑level control: Slide upper‑ and lower‑limit target water‑level values; system will adjust gate opening automatically.

Cloud Platform
- Real‑time Data: Monitor & display equipment status, signal strength, battery voltage, gate state, gate opening height, upstream‑water‑level, downstream‑water‑level, water‑level upper/lower limits and other parameters.
- Historical‑data Query: Gate‑status logs, gate‑opening logs, upstream‑water‑level logs, downstream‑water‑level logs, battery‑voltage logs, etc.
- Operation Log: Historical records of all equipment operations.

Gate Control
- Tick target gate(s). Click control‑mode selector to switch modes as required. Under manual‑mode, click Open / Close / Stop buttons for gate actuation.
- For upstream‑ / downstream‑water‑level control: input upper‑ and lower‑limit target water‑level values, and the system will adjust gate opening automatically.

6.2 Local Operation
Push‑button Control
Press and hold UP button for 1 s to open gate; press and hold STOP button for 1 s to halt movement; press and hold DOWN button for 1 s to close gate. Cut off power supply for emergency stop.

Touch‑screen Operation
Wake‑up touch‑screen by pressing any button (STOP button recommended). Tap UP / STOP / DOWN icons on screen to control gate movement. Users may also enter parameter‑configuration page to set automatic upstream‑ / downstream‑water‑level control.

Small‑screen unit: functions identical to full‑size touch‑screen.
Tap right‑arrow icon to enter login page.

Please contact our company to obtain login password.

Select menu items after login; circular icon at bottom is return‑to‑previous‑page button.

System Settings: Configure opening‑percentage, water‑level upper/lower‑limits, control‑mode and other parameters.

Small‑screen unit: functions identical to full‑size touch‑screen.
Channel‑communication parameters are factory‑preconfigured. Do NOT modify unless absolutely necessary.

System‑commissioning parameters are factory‑preconfigured. Do NOT modify unless absolutely necessary. Contact our technical‑support team for parameter changes.

Bluetooth Control
Launch mobile APP, select Bluetooth device matching station ID and tap to establish connection.

Select Operation‑parameters menu.

Real‑time gate‑status data will be displayed. Tap UP / STOP / DOWN icons to control gate movement.

Users may also configure automatic‑control‑mode and water‑level upper/lower‑limits under System‑parameters menu for automatic‑control operation.

Enter System‑commissioning menu to configure automatic‑control‑mode and water‑level thresholds.
System‑commissioning parameters are factory‑preconfigured. Do NOT modify unless absolutely necessary. Contact our technical‑support team for parameter changes.

Enter Sensor‑parameter menu to configure sensor‑acquisition tasks for sensor‑data access.

Official website: www.gewuiot.com Tel: +86‑15830040128