GW‑SO‑SH1 FDR Frequency Domain Soil Moisture Sensor User Manual

V1.1

Manufacturer: Beijing Gewuiot Technology Co., Ltd.

VersionUpdate ContentDate
V1.0Initial release2021‑03‑10
V1.11. Optimized model and mechanical structure 2. Adjusted partial registers2025‑02‑28

1. Product Overview

GW‑SO‑SH1 is a soil volumetric water content sensor adopting the FDR (Frequency Domain Reflectometer) principle.

  • Enclosure: Sealed with O-ring and thread structure, filled with low-flow acetone-free sealant, achieving sealing performance above IP68.
  • 4-probe design, forming a closed-loop electromagnetic radiation structure for sampling.
  • Equipped with probe guard sleeve to fix probe spacing and guarantee consistent sensor performance.

The sensor features an RS485 interface with standard Modbus protocol; custom non-standard protocols are available. It is suitable for real-time soil moisture monitoring in farmland, forest, grassland and irrigation districts. It can also provide data support for early warning of landslides, mudslides and other geological disasters.

2. Technical Specifications

Basic Parameters

ItemSpecification
ModelGW‑LS‑SH1
Power Supply5~12VDC
Operating CurrentTypical: 16mA; Range: 15‑17mA
Ingress ProtectionIP68
Housing MaterialReinforced modified nylon
Operating Temperature-30~70℃
Probe MaterialStainless steel
Cable LengthStandard 7m
Analog Output0‑2.5VDC

Measurement Parameters

ItemSpecificationRemarks
Measuring Range0‑100% (m³/m³)90% of the sensing coverage is within a cylinder of Φ3cm × 5.8cm around the central probe
Measurement Accuracy±2%(m³/m³) within 0‑50%(m³/m³)Linear discrete deviation probability: 1%
Warm-up TimeApprox. 2s after power-on
Sampling Interval1s

Communication Parameters

ItemSpecificationRemarks
Physical InterfaceRS485Baud rate: 9600
ProtocolMODBUSCustom non-standard protocol supported

3. Power Supply

The sensor accepts DC input from 5V to 12V.

For battery-powered low-power applications, it is recommended that the main controller power on the sensor only for sampling, then cut off power after acquisition to reduce overall power consumption.

4. Calibration

Calibration Tools: Mallet, 200 cm³ core cutter handle, core cutter (height 70mm × inner diameter 70mm), aluminum box, 2000g electronic balance (readability 0.1g), filter paper (fast or medium speed), drying oven (small size is acceptable).

Calibration Formulas: Soil water content indicates the proportion of water among the three phases of soil: solid particles, liquid water and gas. Two commonly used expressions are shown as follows.

① Mass water content θₘ: The ratio of the mass of water Ww to the mass of solid phase — dry soil Ws, namely: θₘ = Ww / Ws

② Volumetric water content θᵥ: The ratio of the volume of water Vw to the total volume of soil V₀, namely: θᵥ = Vw / V₀

Mass water content and volumetric water content can be converted by the formula below: θᵥ = θₘ · ρb

Where ρb refers to soil bulk density, defined as the ratio of dry soil mass to soil volume, namely: ρb = Ws / V₀

5. Protocol Description

Default serial configuration: 9600 baud, 8 data bits, 1 stop bit, no parity, Modbus RTU. Custom protocols can be developed for seamless replacement without modifying host logic.

5.1 Device Address

  • Default address: 1, configurable via command.
  • If the address is lost, send read command to address 0 to identify the actual address.
  • Only one sensor shall be connected on the bus when using address 0.

The sensor embeds calculation formula and outputs volumetric water content directly.

Reference formula for loam soil (0 to saturation): $y= 4.5819x^3 - 7.8022x^2 + 30.99x - 0.375$ Derived in accordance with Specification for Soil Moisture Monitoring.

5.2 Register Map

ParameterRegister AddressData TypeLengthFunction CodeDescriptionData Range
Calibration Equation0x0000Float163/4/16Cubic calibration coefficients
Device Address0x0100Char23/4/6Low byte of Modbus address
Baud Rate0x0200Short23/4/6RS485 baud rate (4800, 9600); default: 48000‑255
Moisture Raw AD0x0400Float4*N3/4Raw AD value (multi-depth float)0‑65535
Volumetric Moisture0x0500Float4*N3/4Soil moisture value (multi-depth float)
Temperature0x0600Float4*N3/4Temperature value (multi-depth float)

5.3 Communication Frames

Write Calibration Equation

Command example: 01 10 00 00 00 08 10 00 00 00 00 00 00 00 00 3F 80 00 00 00 00 00 00 8F B4

Slave AddressWrite Multiple RegistersStart AddressReg CountByte CountFloat0Float0Float1Float0CRC
011000 0000 081000 00 00 0000 00 00 003F 80 00 0000 00 00 008F B4

Modify Baud Rate

Command example: 01 06 02 00 12 C0 84 B1

Slave AddressWrite Single RegisterRegister AddressBaud 4800CRC
010602 0012 C084 B1

Modify Slave Address (set to 3)

Command example: 01 06 01 00 00 03 C8 04

Slave AddressWrite Single RegisterAddress RegisterNew Address = 3CRC
010601 0000 03C8 04

Read Moisture

Read command example: 01 03 05 00 00 06 44 F3

Slave AddressRead Holding RegistersMoisture Start AddressRead 6 RegistersCRC
010305 0000 0644 F3

Response example: 01 03 0C 00 00 00 00 00 00 00 00 00 00 00 00 93 70

Slave AddressFunction CodeByte CountMoisture 1Moisture 2Moisture 3CRC
01030CFloatFloatFloat93 70

Read Temperature

Read command example: 01 03 06 00 00 06 44 F3

Slave AddressRead Holding RegistersTemp Start AddressRead 6 RegistersCRC
010306 0000 0644 F3

Response example: 01 03 0C 00 00 00 00 00 00 00 00 00 00 00 00 93 70

Slave AddressFunction CodeByte CountTemp 1Temp 2Temp 3CRC
01030CFloatFloatFloat93 70

6. Wiring Definition

Wire ColorDefinition
WhiteVCC
BlackGND
BlueRS485+
YellowRS485‑
RedAnalog Output +

Note: Remove sampling resistor on RTU terminal when collecting analog voltage signal.

7. Mechanical Dimensions

GW‑SO‑SH1 size

GW‑SO‑SH1 size

  • Main body diameter: 46 mm
  • Probe length: 60 mm
  • Probe diameter: 3 mm
  • Segmented height of housing: 60 mm, 13 mm, 15 mm

8. Installation Guidelines

GW‑SO‑SH1 ig

1. Step Trench Installation

Dig a stepped trench, insert the sensor horizontally against the step surface. This method effectively prevents sensor settlement.

2. Soil Profile Installation

Excavate a full soil profile to target depths (e.g. 10 cm, 20 cm, 40 cm), install sensors staggered on the vertical face. GW‑SO‑SH1 pi

GW‑SO‑SH1 pi

GW‑SO‑SH1 pi

Installation key: Backfill and compact soil layer by layer. Avoid artificially high moisture readings after rainfall.

Installation Notes

  1. Select locations with fewer stones and roots; avoid slopes and low-lying areas to ensure representative readings.
  2. Keep probes straight or vertical into soil.
  3. Fully bury probes, eliminate gaps around probe base. Air gaps trap water and cause abnormal jumps after rain.
  4. Tap gently on the sensor tail for insertion; do not hammer hard. Stop and relocate if hitting hard objects.
  5. Protect probe spacing. Misalignment reduces accuracy and may cause circuit corrosion or short circuit.

9. Packing List

No.ItemRemarks
1Sensor Main Unit
2Power & Signal Cable

Note: Hard copy manual is not included by default. Contact the factory if required.

10. General Precautions

  1. Protect cable sheath from damage to prevent water ingress.
  2. Strictly avoid reversed wiring, which may burn out the sensor.
  3. Keep probes away from stones and roots. Installation quality directly determines measurement accuracy.
  4. Insert slowly into dry hard soil; never hammer the sensor violently.

Website: www.gewuiot.com Tel: +86 15830040128