GEWU DOCUMENTATION
GW‑SO‑SH1 FDR Frequency Domain Soil Moisture Sensor
GW‑SO‑SH1 is a soil volumetric water content sensor adopting the FDR (Frequency Domain Reflectometer) principle.
What should I know about GW‑SO‑SH1 FDR Frequency Domain Soil Moisture Sensor?
GW‑SO‑SH1 is a soil volumetric water content sensor adopting the FDR (Frequency Domain Reflectometer) principle.
GW‑SO‑SH1 FDR Frequency Domain Soil Moisture Sensor User Manual
V1.1
Manufacturer: Beijing Gewuiot Technology Co., Ltd.
| Version | Update Content | Date |
|---|---|---|
| V1.0 | Initial release | 2021‑03‑10 |
| V1.1 | 1. Optimized model and mechanical structure 2. Adjusted partial registers | 2025‑02‑28 |
1. Product Overview
GW‑SO‑SH1 is a soil volumetric water content sensor adopting the FDR (Frequency Domain Reflectometer) principle.
- Enclosure: Sealed with O-ring and thread structure, filled with low-flow acetone-free sealant, achieving sealing performance above IP68.
- 4-probe design, forming a closed-loop electromagnetic radiation structure for sampling.
- Equipped with probe guard sleeve to fix probe spacing and guarantee consistent sensor performance.
The sensor features an RS485 interface with standard Modbus protocol; custom non-standard protocols are available. It is suitable for real-time soil moisture monitoring in farmland, forest, grassland and irrigation districts. It can also provide data support for early warning of landslides, mudslides and other geological disasters.
2. Technical Specifications
Basic Parameters
| Item | Specification |
|---|---|
| Model | GW‑LS‑SH1 |
| Power Supply | 5~12VDC |
| Operating Current | Typical: 16mA; Range: 15‑17mA |
| Ingress Protection | IP68 |
| Housing Material | Reinforced modified nylon |
| Operating Temperature | -30~70℃ |
| Probe Material | Stainless steel |
| Cable Length | Standard 7m |
| Analog Output | 0‑2.5VDC |
Measurement Parameters
| Item | Specification | Remarks |
|---|---|---|
| Measuring Range | 0‑100% (m³/m³) | 90% of the sensing coverage is within a cylinder of Φ3cm × 5.8cm around the central probe |
| Measurement Accuracy | ±2%(m³/m³) within 0‑50%(m³/m³) | Linear discrete deviation probability: 1% |
| Warm-up Time | Approx. 2s after power-on | |
| Sampling Interval | 1s |
Communication Parameters
| Item | Specification | Remarks |
|---|---|---|
| Physical Interface | RS485 | Baud rate: 9600 |
| Protocol | MODBUS | Custom non-standard protocol supported |
3. Power Supply
The sensor accepts DC input from 5V to 12V.
For battery-powered low-power applications, it is recommended that the main controller power on the sensor only for sampling, then cut off power after acquisition to reduce overall power consumption.
4. Calibration
Calibration Tools: Mallet, 200 cm³ core cutter handle, core cutter (height 70mm × inner diameter 70mm), aluminum box, 2000g electronic balance (readability 0.1g), filter paper (fast or medium speed), drying oven (small size is acceptable).
Calibration Formulas: Soil water content indicates the proportion of water among the three phases of soil: solid particles, liquid water and gas. Two commonly used expressions are shown as follows.
① Mass water content θₘ: The ratio of the mass of water Ww to the mass of solid phase — dry soil Ws, namely: θₘ = Ww / Ws
② Volumetric water content θᵥ: The ratio of the volume of water Vw to the total volume of soil V₀, namely: θᵥ = Vw / V₀
Mass water content and volumetric water content can be converted by the formula below: θᵥ = θₘ · ρb
Where ρb refers to soil bulk density, defined as the ratio of dry soil mass to soil volume, namely: ρb = Ws / V₀
5. Protocol Description
Default serial configuration: 9600 baud, 8 data bits, 1 stop bit, no parity, Modbus RTU. Custom protocols can be developed for seamless replacement without modifying host logic.
5.1 Device Address
- Default address: 1, configurable via command.
- If the address is lost, send read command to address 0 to identify the actual address.
- Only one sensor shall be connected on the bus when using address 0.
The sensor embeds calculation formula and outputs volumetric water content directly.
Reference formula for loam soil (0 to saturation): $y= 4.5819x^3 - 7.8022x^2 + 30.99x - 0.375$ Derived in accordance with Specification for Soil Moisture Monitoring.
5.2 Register Map
| Parameter | Register Address | Data Type | Length | Function Code | Description | Data Range |
|---|---|---|---|---|---|---|
| Calibration Equation | 0x0000 | Float | 16 | 3/4/16 | Cubic calibration coefficients | |
| Device Address | 0x0100 | Char | 2 | 3/4/6 | Low byte of Modbus address | |
| Baud Rate | 0x0200 | Short | 2 | 3/4/6 | RS485 baud rate (4800, 9600); default: 4800 | 0‑255 |
| Moisture Raw AD | 0x0400 | Float | 4*N | 3/4 | Raw AD value (multi-depth float) | 0‑65535 |
| Volumetric Moisture | 0x0500 | Float | 4*N | 3/4 | Soil moisture value (multi-depth float) | |
| Temperature | 0x0600 | Float | 4*N | 3/4 | Temperature value (multi-depth float) |
5.3 Communication Frames
Write Calibration Equation
Command example:
01 10 00 00 00 08 10 00 00 00 00 00 00 00 00 3F 80 00 00 00 00 00 00 8F B4
| Slave Address | Write Multiple Registers | Start Address | Reg Count | Byte Count | Float0 | Float0 | Float1 | Float0 | CRC |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 10 | 00 00 | 00 08 | 10 | 00 00 00 00 | 00 00 00 00 | 3F 80 00 00 | 00 00 00 00 | 8F B4 |
Modify Baud Rate
Command example:
01 06 02 00 12 C0 84 B1
| Slave Address | Write Single Register | Register Address | Baud 4800 | CRC |
|---|---|---|---|---|
| 01 | 06 | 02 00 | 12 C0 | 84 B1 |
Modify Slave Address (set to 3)
Command example:
01 06 01 00 00 03 C8 04
| Slave Address | Write Single Register | Address Register | New Address = 3 | CRC |
|---|---|---|---|---|
| 01 | 06 | 01 00 | 00 03 | C8 04 |
Read Moisture
Read command example:
01 03 05 00 00 06 44 F3
| Slave Address | Read Holding Registers | Moisture Start Address | Read 6 Registers | CRC |
|---|---|---|---|---|
| 01 | 03 | 05 00 | 00 06 | 44 F3 |
Response example:
01 03 0C 00 00 00 00 00 00 00 00 00 00 00 00 93 70
| Slave Address | Function Code | Byte Count | Moisture 1 | Moisture 2 | Moisture 3 | CRC |
|---|---|---|---|---|---|---|
| 01 | 03 | 0C | Float | Float | Float | 93 70 |
Read Temperature
Read command example:
01 03 06 00 00 06 44 F3
| Slave Address | Read Holding Registers | Temp Start Address | Read 6 Registers | CRC |
|---|---|---|---|---|
| 01 | 03 | 06 00 | 00 06 | 44 F3 |
Response example:
01 03 0C 00 00 00 00 00 00 00 00 00 00 00 00 93 70
| Slave Address | Function Code | Byte Count | Temp 1 | Temp 2 | Temp 3 | CRC |
|---|---|---|---|---|---|---|
| 01 | 03 | 0C | Float | Float | Float | 93 70 |
6. Wiring Definition
| Wire Color | Definition |
|---|---|
| White | VCC |
| Black | GND |
| Blue | RS485+ |
| Yellow | RS485‑ |
| Red | Analog Output + |
Note: Remove sampling resistor on RTU terminal when collecting analog voltage signal.
7. Mechanical Dimensions


- Main body diameter: 46 mm
- Probe length: 60 mm
- Probe diameter: 3 mm
- Segmented height of housing: 60 mm, 13 mm, 15 mm
8. Installation Guidelines

1. Step Trench Installation
Dig a stepped trench, insert the sensor horizontally against the step surface. This method effectively prevents sensor settlement.
2. Soil Profile Installation
Excavate a full soil profile to target depths (e.g. 10 cm, 20 cm, 40 cm), install sensors staggered on the vertical face.



Installation key: Backfill and compact soil layer by layer. Avoid artificially high moisture readings after rainfall.
Installation Notes
- Select locations with fewer stones and roots; avoid slopes and low-lying areas to ensure representative readings.
- Keep probes straight or vertical into soil.
- Fully bury probes, eliminate gaps around probe base. Air gaps trap water and cause abnormal jumps after rain.
- Tap gently on the sensor tail for insertion; do not hammer hard. Stop and relocate if hitting hard objects.
- Protect probe spacing. Misalignment reduces accuracy and may cause circuit corrosion or short circuit.
9. Packing List
| No. | Item | Remarks |
|---|---|---|
| 1 | Sensor Main Unit | |
| 2 | Power & Signal Cable |
Note: Hard copy manual is not included by default. Contact the factory if required.
10. General Precautions
- Protect cable sheath from damage to prevent water ingress.
- Strictly avoid reversed wiring, which may burn out the sensor.
- Keep probes away from stones and roots. Installation quality directly determines measurement accuracy.
- Insert slowly into dry hard soil; never hammer the sensor violently.
Website: www.gewuiot.com Tel: +86 15830040128